site stats

Grace fireproof thickness chart

Webmethod 102-120 pcf unit weight, 3000 psi compressive strength, vibrated, 4 to 7 percent air. Min thickness as measured to crests of steel floor and form units, 2-1/2 in. 3. Welded … http://www.isolatek.com/storage/designs_thickness/300_400/thickness_charts/X790.pdf

Chartek 1709 - AkzoNobel

WebIt is in the fireproofing contrac- Thickness Test: This test is performed by using a thickness gauge, as it appears in the drawing. This gauge is approved by ASTM E605, … ios scrollbar not showing https://antiguedadesmercurio.com

Monokote MK -6 HY - Fireproofing

http://avi-sa.com/datasheets/Product%20Datasheet_Monokote%20Z-106.pdf WebNA. Non-Load Restricted. Beam Only Design for Roof Assemblies. UL S750. PDF. NA. S750 Unres All. S750 Unres MK6GF. S750 Unres Z106HY. http://www.archcoatings.com/product-pdfs/Grace%20products/Z106.pdf on time scoopers

UL Designs & Thickness — Roof Assemblies Resource GCP …

Category:MONOKOTE®MK-6®, MK-6/HY®and MK-6s Product data …

Tags:Grace fireproof thickness chart

Grace fireproof thickness chart

SPRAY-APPLIED FIREPROOFING MATERIAL - Durham, NC

WebSOUTHWEST TYPE 5GP A 15 lb./ft³ (240 kg/m³) SFRM intended for the fire protection of interior structural columns, beams, joists, decks, walls, roofs, girders, floors and pre-cast concrete units. It is tested and certified for fire resistance ratings up to 4 hours. Southwest Type 5GP is a trademark of the Southwest Fireproofing Products Company. WebUL Designs & Thicknesses for CAFCO 300 and CAFCO 400 Series passive fireproofing materials for the commercial and construction industry. (973) 347-1200 Select language

Grace fireproof thickness chart

Did you know?

WebSpray-Applied Fire Resistive Materials — Applied by mixing with water and spraying in one or more coats to a final thickness as shown in the tables below, to steel beam surfaces … WebThe thickness of Spray-Applied Fire Resistive Materials shown in the table below are only applicable when the beams are supporting solid, normal weight, concrete slabs or floor assemblies containing only fluted floor or form units, topped with normal weight concrete. ... GRACE KOREA INC —Types MK-6/HY, MK-6/HY Extended Set, MK-10 HB, MK-10 ...

WebC. Fireproofing will be considered defective if it does not pass tests and inspections. 1. Remove and replace fireproofing that does not pass tests and inspections, and retest. 2. Apply additional fireproofing, per manufacturer's written instructions, where test results indicate insufficient thickness, and retest. http://www.ritewaythermal.com/wp-content/uploads/2015/09/MK-288R-Prod_Select_Guide.pdf

WebProduct Testing. All of the products that we offer have undergone rigorous testing by both ASTM and Underwriters Laboratory (UL) to verify their physical properties and determine their performance during a fire. UL fire tests are conducted on various construction assemblies and data is used to extrapolate a required thickness for each ... WebThe min thickness of Spray-Applied Fire Resistive Materials required for various fire resistance ratings of contour sprayed or boxed wide flange columns are shown in the table below: Column Size W/D Min Thkns In. 1 Hr 1-1/2 Hr 2 Hr 3 Hr 4 Hr W6x9 0.33 15/16 1-1/4 1-9/16 2-1/8 2-11/16 W6x12 0.43 13/16 1-1/8 1-7/16 2 2-9/16

WebFeb 14, 2024 · UL Designs & Thickness — Floor Assemblies. Submittal Generator UL Design Selector Click here for Roof Assemblies and Columns Unrestrained Beam Thickness Tables Restrained Beam Thickness Tab... READ MORE. MONOKOTE® Z-146 Product … Grace Ice & Water Shield® ... Click here for Floor Assemblies and Roof Assemblies … GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 450, …

Web... example of this is demonstrated in Table 1 by the increase in thickness of the amount of fireproofing required to protect a steel member when exposed to a UL 1709-type exposure versus an... ios screenshot settingsWebW R GRACE & CO - CONN — Type Strux 90/40. 3. Steel Floor and Form Units* — Composite 1-1/2, 1-5/8, 2 or 3 in. deep galv units or 4-1/2 in. deep noncomposite galv units. Fluted units may be uncoated or phosphatized/painted. Min gauges are 22 MSG for fluted and 20/20 MSG for cellular units. The following combinations of units may be used: ios screenshot iphone 11Weba. Application of Type Z-106 fireproofing can be made in the following sequence: 1. For thickness of approximately 13mm (1/2 in.) or less, apply in one pass. 2. For thickness of 16mm (5/8 in.) or greater, apply subsequent passes after the first coat has set. b. Type Z-106 fireproofing material shall not be used if on time seriesWebSteel Fireproofing 2. Manufacturer Grace Construction Products 62 Whittemore Avenue Cambridge, MA 02140 (866) 333-3SBM (3726) (617) 876-1400 Fax: (617) 498-4311 ... Field inspection for thickness, density and bond strength by an independent agency is recommended and may be required by the local building code jurisdiction. Any areas with ios screenshot sizeWebIt is in the fireproofing contrac- Thickness Test: This test is performed by using a thickness gauge, as it appears in the drawing. This gauge is approved by ASTM E605, and is used by Under- writers Laboratories. It is light, durable, and … ios scroll fixed up downWebApplication of Monokote Fireproofing can be made in the following sequence: For thicknesses of approximately 1⁄2 in. (13 mm) or less, apply in one pass. For thicknesses of 5⁄8 in. (16 mm) or greater, apply subsequent passes after the first coat has set. on time service corporationWebchart is applicable to MK-6 HY and is also found in the Association for Specialist Fire protection,( ASFP) “Yellow Book”. Accessory Products Grace has developed the Monokote MK-6 HY Extended Set to allow lines to be left filled at the end of the day, overnight or over the weekend, therefore eliminating the need to pump in or pump out. on time seed spreader parts