WebDec 26, 2024 · poll函数讲解***events revents. poll提供的功能与select类似,不过在处理流设备时,它能够提供额外的信息。. events和revents是通过对代表各种事件的标志进行逻辑或运算构建而成的。. events包括要监视的事件,poll用已经发生的事件填充revents。. poll函数通过在revents中 ... WebNov 23, 2024 · The ts2phc program will introduce clock synchronization which is orthogonal to the direction in which PPS is emitted (from the master to the slave). To have a more consistent terminology, we can avoid using the ultra-generic term "master" and replace it with "PPS source", which describes the role of the data structure in the new interpretation ...

ts2phc(8): Synchronizes one or more PTP Hardware Clocks using exter…

WebRETURN VALUE top On success, poll() returns a nonnegative value which is the number of elements in the pollfds whose revents fields have been set to a nonzero value (indicating an event or an error). A return value of zero indicates that the system call timed out before any file descriptors became read. WebRETURN VALUE top On success, poll() returns a nonnegative value which is the number of elements in the pollfds whose revents fields have been set to a nonzero value (indicating … greenhouses agriculture https://antiguedadesmercurio.com

poll() - QNX

WebJan 30, 2024 · The ts2phc program works (or should work) all by itself. > Command : > ts2phc -f ts2phc.cfg -m -s generic > ts2phc[503.770]: poll returns zero, no events > … WebDec 23, 2024 · If timeout is greater than zero, it specifies a maximum interval (in milliseconds) to wait for any file descriptor to become ready. If timeout is zero, then poll () will return without blocking. If the value of timeout is -1, the poll blocks indefinitely. Maximum interval to wait for the poll to complete, in milliseconds. If this value is 0 ... WebSymmetrically no operation is really necessary for POLLOUT, but you usually want to call the next write () as soon as possible. So as a rule of thumb POLLIN -> read, POLLOUT -> write. You should also reset you pollfd struct before calling poll again. fds [0].fd = sck; fds [0].events = POLLIN; fds [0].revents = 0; ret = poll ( fds, 1, 2000); //2 ... flybuys lost member number

[Linuxptp-devel] [PATCH v3 2/2] ts2phc: Add PTP as a source of ToD

Category:poll () ingores incoming data when called with 0 timeout

Tags:Ts2phc poll returns zero no events

Ts2phc poll returns zero no events

Testptp - NVIDIA 5T Technology User Manual v1.0 - NVIDIA …

WebHi, I'm trying to get GPIO Interrrupt functionality working using sysfs and poll calls. The problem appears to be that the poll call is always returnng immediately and is not triggering on the actualy rising edge. I have configured the kernel for this GPIO to be an input which does work correctly. I've also configured the GPIO (114) correctly ... Webts2phc.pulsewidth. The expected pulse width of the external PPS signal in nanoseconds. When ts2phc.extts_polarity is both, the given pulse width is used to detect and discard the …

Ts2phc poll returns zero no events

Did you know?

WebA tag already exists with the provided branch name. Many Git commands accept both tag and branch names, so creating this branch may cause unexpected behavior.

Web[Linuxptp-devel] [PATCH v3 2/2] ts2phc: Add PTP as a source of ToD PTP IEEE 1588 stack for Linux Brought to you by: rcochran. Summary Files Reviews Support Code Mailing Lists WebDec 20, 2024 · If none of the defined events occurs on any selected file descriptor, poll() waits at least timeout milliseconds for an event to occur on any of the selected file descriptors. If the value of timeout is 0, poll() returns immediately. If the value of timeout is -1, poll() blocks until a requested event occurs or until the call is interrupted.

WebUser space PTP stack for the GNU/Linux operating system. - linuxptp/ts2phc_pps_sink.c at master · richardcochran/linuxptp WebOn the contrary, if epoll is used too much, epoll will be more efficient_ CTL, the efficiency is still slightly lower. However, once idle connections is used to simulate WAN environment, epoll is far more efficient than selected / poll. 3. Use MMAP to accelerate the message passing between kernel and user space.

WebJan 30, 2024 · The ts2phc program works (or should work) all by itself. > Command : > ts2phc -f ts2phc.cfg -m -s generic > ts2phc[503.770]: poll returns zero, no events > …

WebJul 26, 2024 · I'm using a framework which I give a socket to and it will call my callback if there is data to be read (or if timeout). However it keeps calling me as fast as my cpu can handle although there is no data to be read from the socket. [pid 16586] poll ( [ {fd=16, events=POLLIN}, {fd=17, events=POLLIN}], 2, 1000) = 2 ( [ {fd=16, revents=POLLIN ... green house salad companyWebUp to maxevents are returned by epoll_wait (). The maxevents argument must be greater than zero. The timeout argument specifies the number of milliseconds that epoll_wait () will block. Time is measured against the CLOCK_MONOTONIC clock. A call to epoll_wait () will block until either: • a file descriptor delivers an event; • the call is ... greenhouses airbnbWebThe default is 0.0. ts2phc.nmea_remote_host, ts2phc.nmea_remote_port. Specifies the serial port character device providing ToD information when using the "nmea" PPS signal … greenhouse salad co shreveport laWebRETURN VALUE On success, poll() returns a nonnegative value which is the number of elements in the pollfds whose revents fields have been set to a nonzero value (indicating an event or an error). A return value of zero indicates that the system call timed out before any file descriptors became read. green house salad company shreveportWebJul 16, 2014 · For pipes and sockets, it depends on the operating system. Linux sets POLLHUP when the program on the writing end of a pipe closes the pipe, and sets POLLIN POLLHUP when the other end of a socket closed the socket, but POLLIN only for a socket shutdown. Recent *BSD set POLLIN POLLUP when the writing end of a pipe closes … greenhouse salad co lake charles laWebJan 21, 2024 · [Linuxptp-devel] facing problem in running in ts2phc on ubuntu 18.04 Nikhil Gupta Thu, 21 Jan 2024 23:32:57 -0800 Hello, I am facing problem in running ts2phc on … flybuys masterchefWebAug 2, 2014 · 2. My application checks for incoming data in a TCP socket by calling poll () with zero timeout. 99% of the time it works fine, when there are data on the socket it sets the POLLIN flag. Sometimes however there are data on the socket (I see the message on wireshark), but poll () returns 0 (timed out) and does not set the POLLIN flag. greenhouses albany ny